Basic Info.
Transport Package
The Wooden Case
Specification
The wooden case
Product Description
Overview
This product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic development, the whole product has a small volume, easy installation and maintenance, low noise, low loss, anti-theft, too negative
Strong load capacity, full protection and other characteristics. It is suitable for new residential area, green belt, park, station hotel, construction site, airport and other places.
Yb27-12 series American preinstalled box substation, suitable for 10kV loop power supply, dual power supply or terminal power supply system, as transformer, metering, compensation control and protection device.
This product conforms to the following standards: GB/T17467-1998 "high voltage and low voltage pre-installed Substation", DL/T537-93 "technical conditions for ordering 6-35kV box substation"
Model and meaning
Functions and Features
Full insulation, full sealing, less maintenance, reliable to ensure personal safety;
Compact structure, volume is only 1/3-1/5 of the same capacity eurovariable, low height;
Can use separate box structure, avoid oil pollution in transformer tank;
High pressure side adopts double fuse full range protection, greatly reducing the cost:
Can be used for ring network, can also be used for terminal, cable head can be in 200A load current emergency plug;
The box body adopts honeycomb double sandwich composite board, which can isolate temperature and dissipate heat.
The low voltage side is equipped with an electronic missing phase protector, which can quickly break the main drive switch when abnormal voltage occurs in the system.
High pressure side oil-immersed load switch or SF6 load switch, can be electrically upgraded, for the realization of network automation to lay a foundation.
Adopt oil-immersed S9 or S11 series transformer with better performance.
Service environment conditions
The altitude does not exceed 1000m;
Ambient temperature: -35 "C~+40C;
Relative humidity: the daily average is not more than 95%, the monthly average is not more than 90%;
Installation place: no fire, explosion danger, chemical corrosive gas and well-ventilated place, the inclination of the ground is not more than 3°.
Main technical parameters
Technical parameter table of preinstalled substation
number | name | unit | data |
1 | The rated voltage | kv | 10/0.4 |
2 | Maximum operating voltage | kv | 12 |
3 | Rated frequency | Hz | 50 |
4 | Nominal capacity | kVA | 50-1600 |
5 | 1 minute power frequency withstand voltage | kv | 35 |
6 | Lightning impulse voltage | kv | 75 |
7 | Cooling way | | Oil-immersed self-cooling |
8 | Breaking current of high voltage backup fuse | kA | 50 |
9 | Breaking current of plug-in fuse | kA | 2.5 |
10 | The environment temperature | 0ºC | -35- +40 |
11 | The coil allows temperature rise | 0ºC | 65 |
12 | No load voltage regulation | | ±5%,±2x2.5% |
13 | The noise level | db | 50 |
14 | Protection grade | | IP43 |
Transformer technical parameter table
The new S9 series transformer body is selected, with low loss, good overload capacity and strong short-circuit resistance. All fasteners are treated with anti-loosening and free of hanging core. S10 series and S11 series transformers with better performance can also be selectedcapacity | KV voltage | Connection group id | No load current % | No load loss KW | Resistance voltage KV | Load loss KW |
KVA | High pressure | low pressure | S9 | S10 | S11 | S9 | S10 | S11 | S9 | S10 | S11 |
50 | 10±5% of ±2x2.5% | 0.4 | Dyn11 of Yyn0 | 2.0 | 1.9 | 0.75 | 0.17 | 0.15 | 0.12 | 4.0 | 0.87 | 0.83 | 0.87 |
63 | 1.9 | 1.8 | 0.7 | 0.2 | 0.18 | 0.14 | 1.04 | 0.99 | 1.04 |
80 | 1.9 | 1.7 | 0.7 | 0.25 | 0.22 | 0.175 | 1.25 | 1.2 | 1.25 |
100 | 1.8 | 1.55 | 0.65 | 0.29 | 0.26 | 0.2 | 1.5 | 1.42 | 1.5 |
125 | 1.7 | 1.45 | 0.65 | 0.34 | 0.3 | 0.235 | 1.8 | 1.72 | 1.8 |
160 | 1.6 | 1.3 | 0.6 | 0.4 | 0.36 | 0.27 | 2.2 | 2.12 | 2.2 |
200 | 1.5 | 1.2 | 0.55 | 0.48 | 0.43 | 0.33 | 2.6 | 2.5 | 2.6 |
250 | 1.4 | 1.1 | 0.5 | 0.56 | 0.5 | 0.39 | 3.05 | 2.9 | 3.05 |
315 | 1.4 | 1.0 | 0.45 | 0.67 | 0.29 | 0.465 | 3.65 | 3.45 | 3.65 |
400 | 1.3 | 1.0 | 0.4 | 0.8 | 0.71 | 0.56 | 4.3 | 4.15 | 4.3 |
500 | 1.2 | 1.0 | 0.4 | 0.96 | 0.85 | 0.67 | 5.15 | 4.82 | 5.15 |
630 | 1.1 | 0.8 | 0.4 | 1.2 | 1.6 | 0.81 | 4.5 | 6.2 | 5.86 | 6.2 |
800 | 1.0 | 0.7 | 0.35 | 1.4 | 1.23 | 0.98 | 7.5 | 7.2 | 7.5 |
1000 | 1.0 | 0.6 | 0.3 | 1.7 | 1.5 | 1.15 | 10.3 | 9.8 | 10.3 |
1250 | 0.9 | 0.6 | 0.27 | 1.95 | 1.72 | 1.36 | 12.0 | 12.2 | 12.0 |
Technical parameter table of load switch
Load switch for oil immersion, three-phase linkage switch, spring operating mechanism; It can be operated by opening and closing with load. The opening and closing speed has nothing to do with the operating force. There are two station, four station T, four station V and so on for choice.number | name | unit | Four station ring network load switch | Two station ring network load switch |
1 | Rated current | | A | 630 | 630 |
2 | Rated short circuit switching current | | kA | 31.5 | 31.5 |
3 | Rated short-time withstand current | | kA | 12.5 | 12.5 |
4 | Rated short time tolerance | | S | 2 | 2 |
5 | Mechanical life | | times | 2000 | 2000 |
6 | Lightning resistance | And over the ground | kV | 75 | 75 |
7 | Voltage peak full wave | The isolation of fracture | 85 | 42 |
8 | 1 min power frequency resistance | And over the ground | kV | 42 | 42 |
9 | By the voltage | The isolation of fracture | 48 | 48 |
10 | Rated peak tolerance current | | kA | 31.5 | 31.5 |
Fuse technical parameters (recommended table for selection and configuration of oil-immersed fuse of our company)
American box variable high pressure side by the backup protection fuse and plug fuse series to provide full range of protection, simple principle, economic and reliable; The backup protection fuse is oil-immersed high-voltage current limiting fuse, which has a large breaking capacity and can only operate when the transformer is in internal failure. The plug-in fuse is equipped with double-sensitive fuse, which can provide dual protection of current and temperature. After the double-sensitive fuse is broken, the fuse can be easily replaced on site.
number | Three-phase transformer capacity(kva) | Primary voltage of transformer (10kV) |
XRNT Rated current (A) | PRNT1 Overload protection Rated current (A) |
1 | 30 | 10 | 6 |
2 | 50 | 16 | 8 |
3 | 80 | 16 | 10 |
4 | 100 | 20 | 15 |
5 | 125 | 25 | 15 |
6 | 160 | 31.5 | 25 |
7 | 200 | 40 | 25 |
8 | 250 | 50 | 40 |
9 | 315 | 63 | 40 |
10 | 400 | 63 | 40 |
11 | 500 | 80 | 50 |
12 | 630 | 100 | 50,65 |
13 | 800 | 125 | 65 |
14 | 1250 | 160 | 100 |
15 | 1600 | 200 | 140 |
Cases of variable structure
The box structure of the product is composed of three parts: high pressure interval, low pressure interval and tank interval. The high voltage interval includes high voltage cable accessories, load switch, no load regulating tap switch, plug fuse, pressure release valve, oil level meter, oil temperature meter and oil discharge valve. The low-voltage interval includes low-voltage bushing, low-voltage meter, circuit breaker and capacitor compensation. Transformer windings and iron cores, radiators, high voltage load switches and fuses are all in the tank. According to the requirements of the scheme, the box variable structure can be designed to design the finished font or mesh font as shown in the figure below.
Address:
Zhejiang Wenzhou Yueqing, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Security & Protection
Company Introduction:
Zhejiang Zhuowoma Electric Technology Co., Ltd. is a diversified enterprise specialized in the development, manufacturing, sales andservice of high-voltage power transmission and distribution. Products covering the industry of high-voltage electrical appliances, electric transmission and distribution equipment, construction, electric automation, etc, with switchgear series, 10-35KV European type series, American type power cable distributi on box series, high-voltage circuit breaker series, high-voltage load switch series, high-voltage fuse series, high-voltage isolator series, high-tension lightning arrester series, high-voltagetransformer series, ceramic wall brushing/insulator series and full high-voltage set accessories. Factory have passed the ISO9001: 2000 quality management system certification and products have access to the production licence with "CCC" certification.
Professional technicians create excellent quality for you, and dedicated teamwork provides you with excellent comprehensive services. The company always implements the business philosophy of "people-oriented, integrity and win-win", and adheres to the principle of "customer first, maintaining capital and small profits". Provide excellent products and service to new and old customers.
Our service brings win-win cooperation:
1. Quick response of pre-sales helps you get your orders.
2. Excellent productions service let you known each step we made.
3. Reliable quality solves your after-sales headache.
4. Long-term quality assurance ensures your purchase without hesitation.